Xantrex XW 6048 programming ENTER + UP + DOWN for advanced mode from System Status display, enter "menu" -> "XW6048 00" -> "Advanced Settings" ================ System Settings XW6048 00 (XW6048 00: menus) XW AGS 00: (XW AGS 00: menus) XW SCP xx: (XW SCP xx: menus) Clock: ================ XW6048 00: menus XW6048 00: Setup ------------- Advanced Settings --------------------------------------> Inverter Settings -> XW6048 00: Inv Meters Charger Settings -> XW6048 00: Chg Inverter [ Disabled] [ Enabled] AC Settings -> XW6048 00: AC Search Mode [ Disabled] [ ] Grid Support -> XW6048 00: Grid Grid Support [ Disabled] [ ] Gen Support -> XW6048 00: Gen Charger [ Disabled] [ Enabled] Aux Settings -> XW6048 00: Aux Force Chg Copy From Multi Unit Config Mode [ Operating] Restore Defaults Clear Faults Warnings Adv Features -> XW6048 00: Adv Features View Device Info XW6048 00: Inv ------------- Low Batt Cut Out [ 44V] [ 45.5V] per Fullriver 45.0V for 5 min is OK LBCO Delay [ 10s] [ 300s] High Batt Cut Out [ 70V] [ 62V] 2.58V per cell (2.7Vpc seems to be the high limit, 65V) Search Watts [ 50W] [ ] Search Delay [ 2s] [ ] *Low Battery Cut Out Hysteresis [ 2.0] [ ] XW6048 00: Chg Note: per Schneider, the W48 warning ------------- occurs at LBCO + 1.0V Batt Type [ Flooded] [ Custom] Custom Settings Eqlz Support [ Enabled] [ Disabled] Eqlz Voltage [ 64.0V] [ *0.0V] ("value could not be changed") Bulk Voltage [ 57.6V] [ 58.8V] Absorb Voltage [ 57.6V] [ 58.8V] per Fullriver Float Voltage [ 54.0V] [ 54.7V] to get 54.8V at batteries at 77degF/25degC Batt Temp Comp [ -108mV/C] [ -96mV/C] *Maximum Discharge Current [ 150] [ ] *Maximum Discharge Time Interval [ 10] [ ] Batt Capacity [ 440Ah] [ 335Ah] Max Chg Rate [ 100%] [ 80%] per Fullriver == 80A, less than 81A allowable *Maximum Bulk Charge Current [ 140.0] [ 67.0] *Maximum Absorption Charge Current [ 140.0] [ 67.0] *Maximum Float Charge Current [ 140.0] [ 1.0] Charge Cycle [ 2Stage] [ 3Stage] Default Batt Temp [ Warm] [ ] ReCharge Volts [ 50V] [ 47V] temp compensated level at which charge cycle begins Absorb Time [ 180min] [ 60min] Fullriver says 47V is fine, "middle of the range" ChgBlockStart [ 0:00] [ ] ChgBlockStop [ 0:00] [ ] XW6048 00: AC ------------- AC Priority [ AC1] [ AC2] AC1 Breaker [ 60A] [ 50A] charging current limited to 80% == 40A AC1 Lo Volt [ 106V] [ ] AC1 Hi Volt [ 132V] [ ] AC1 Lo Freq [ 55Hz] [ ] AC1 Hi Freq [ 65Hz] [ ] *AC1 Transfer Switch Delay [ 12] [ ] AC2 Breaker [ 60A] [ 26A] charging current limited to 80% AC2 Lo Volt [ 80V] [ ] set to 35A for net 6720W AC2 Hi Volt [ 138V] [ ] or 30A for net 5760W AC2 Lo Freq [ 55Hz] [ ] or 26A for net 5000W AC2 Hi Freq [ 65Hz] [ ] *AC2 Transfer Switch Delay [ 36] [ ] *?? Active Power Control ------------- GFS Enable [ Disabled] [ ] API Frequency Start Level [ 59.0] [ ] API Frequency Stop Level [ 58.50] [ ] API Frequency Recover Level [ 59.70] [ ] API Gradient With Time [ 10] [ ] APR Frequency Start Level [ 60.20] [ ] APR Frequency Stop Level [ 61.00] [ ] APR Frequency Recover Level [ 60.05] [ ] APR Gradient With Frequency [ 40] [ ] APR Gradient With Time [ 10] [ ] XW6048 00: Grid ------------- Grid Supp Volts [ 53V] [ 54.8V] set to same as Float Voltage Sell [ Disabled] [ ] (or slightly higher) *Maximum Sell Scale Percentage [ 100] [ ] Max Sell Amps [ 27.0A] [ 0.0A] per Sandra Load Shave [ Disabled] [ ] Load Shave Amps [ 40.0A] [ ] LoadShaveStart [ 0:00] [ ] LoadShaveStop [ 0:00] [ ] *Maximum Reactive Capacitive Power [ 0.00] [ ] *Maximum Reactive Inductive Power [ 0.00] [ ] *Maximum Reactive Power Grid Voltage [ 0.00] [ ] *Minimum Reactive Power Grid Voltage [ 0.00] [ ] *Inductive Voltage Set Point [ 0.00] [ ] *Capacitive Voltage Set Point [ 0.00] [ ] *Voltage Threshold To Start/Stop Excitation [ 0.00] [ ] *Excitation Control Delay Time [ 0.00] [ ] *Sell Block Start [ 12:00AM] [ ] *Sell Block End [ 12:00AM] [ ] *?? Grid Voltage Support ------------- GVS Enable/Disable [ Disable] [ ] XW6048 00: Gen ------------- GenSupp Mode [ Disabled] [ Enabled] GenSupp Amps [ 20.8A] [ ] won't go over 80% of AC2 Breaker which is actual max draw from the generator XW6048 00: Aux inverter supports generator when load exceeds ------------- GenSupp Amps for 1-2 seconds, until load drops Manual Aux [ManualOff] [Automatic] by 2A+10%, i.e. 16.8A or 4KW Active Lvl [ActiveHigh] [ ] Trig Src [ LowBattV] [ ] Trigger Level [ 44.0V] [ 46.7V] keep below AGS Start DCV 15min/2 hr trigger voltage Trigger Delay [ 1sec] [ 60sec] don't delay, generator should have started already... Clear Level [ 48.0V] [ ] Clear Delay [ 1sec] [ 10sec] avoid transient conditions *High Battery Trigger Set [ 56.0] [ ] *High Battery Trigger Set Delay [ 1.0] [ ] *High Battery Trigger Clear [ 52.0] [ ] *Low Temperature Trigger Set [ 0.0] [ ] *Low Temperature Trigger Set Delay [ 1.0] [ ] *Low Temperature Trigger Clear [ 5.0] [ ] *Low Temperature Trigger Clear Delay [ 1.0] [ ] *High Temperature Trigger Set [ 45.0] [ ] *High Temperature Trigger Set Delay [ 1.0] [ ] *High Temperature Trigger Clear [ 35.0] [ ] *High Temperature Trigger Clear Delay [ 1.0] [ ] *Heat Sink High Temperature Trigger Set [ 100.0] [ ] *Heat Sink High Temperature Trigger Set Delay [ 1.0] [ ] *Heat Sink High Temperature Trigger Clear [ 95.0] [ ] *Heat Sink High Temperature Trigger Clear Delay [ 1.0] [ ] *Auxiliary Output Trigger Source [Low Battery Voltage] *Auxiliary Output Trigger Start [ 12:00AM] [ ] *Auxiliary Output Trigger End [ 12:00AM] [ ] *State Of Charge Level To Start [ 25] [ ] *State Of Charge Level To Stop [ 90] [ ] *State Of Charge Start Delay [ 1.00] [ ] *State Of Charge Stop Delay [ 1.00] [ ] If the battery battery voltage slowly drifts down then the generator will start before it drops to the LoWBattV trigger. If the batteries are being slammed or the generator hasn't started then we don't want to abuse the batteries, so kill the Desirable Loads Panel (DLP) quickly. It stays off until the batteries are more or less recovered. XW6048 00: Multi ------------- (do not enter -- will kill power) XW6048 00: Adv Features ------------- RPO [ Disabled] [ ] Power Save [ Disabled] [ ] Sell Dly 40s [ Disabled] [ ] GenSupp Plus [ Disabled] [ ] enable only for generators under 5kW *AC Coupling [ Enable] [ ] *Battery Energy Balance [ Disable] [ ] *Peak Load Shaving Delay[ Disable] [ ] *Remote Sell [ Disable] [ ] *External Transfer Contactor [ Disable] [ ] *AC Transient Over Voltage Disconnect [ Disable] [ ] -------- ================ XW AGS 00: menus from System Status display, enter "menu" -> "XW AGS 00" -> "Advanced Settings" XW AGS 00: Setup ------------- Advanced Settings GenMode [ManualOff] [Automatic] Mode [Operating] [ ] Put in Standby to disable manual or automatic Clear Faults Warnings generator starting View Device Info XW AGS 00: Setup ------------- Advanced Settings GenMode [ManualOff] XW AGS 00: Config ------------- QT [ Enabled] [ Disabled] QT Begin [ 21:00] [ ] QT End [ 8:00] [ ] Gen Type [ 2] [ 14] Type 14 is "Run with..." using Relay 1 (14-16) only Cfg Trigger (XW AGS 00: Triggers) (p2-23,p3-10) Cfg Gen (XW AGS 00: Gen) Relay 1, Run/Stop(Ignition) (14-16) is used Multi-Unit Config (do not enter) Relay 2, Start(Cranking) (17-18) is not used Restore Defaults Relay 3, Preheat(Glow) (19-20) is not used XW AGS 00: Triggers ------------- Start DCV 30 Sec [ 44.5V] [ 46.5V] see Note 1 (can't disable) Start DCV 15 Min [ Disabled] [ 47.0V] Start DCV 2 hr [ Disabled] [ 47.5V] and Aux: Trigger Level Start DCV 24 hr [ Disabled] [ 48.0V] Stop Float [ Disabled] [ Enabled] 48.0 24hr gen start in 24 hours Stop Absorb [ Enabled] [ Disabled] 47.2 2hr gen start in 126 min StopV [ Disabled] [ 60.0V] just in case 46.8 15min gen start in 21 min Temp1 [ Disabled] [ Enabled] see Note 3 46.7 60sec DLP cutout in 1 min Temp2 [ Disabled] [ ] 46.4 30sec gen start in 6.5 min Load [ Disabled] [ Enabled] Strt Load [ 10.0A] [ ] five minute duration (2400W) Stop Load [ 7.0A] [ ] one minute duration (1680W) *AC Current Trigger Start Delay [ 5.0min] [ ] 5min delay + ~6min startup means 11min for generator power *AC Current Trigger Stop Delay [ 1.0min] Note 1: see README.voltlog should be higher than LBCO per manual, Schneider tech support says by 2.0V from empirical measurements the 75% state-of-charge level corresponds to about 47.8V @ ~1500W The Aux "Trigger Level" should be lower than the 15min and 2hr AGS trigger levels, so the generator will have a chance to start before the DLP is disconnected. If the grid goes down with a battery voltage below 46.5 then we lose the DLP immediately. Note 3: Schneider tech support (2014-09-29) says that the Temp1 trigger will only work when AC1 is not present and with a 30 second delay XW AGS 00: Gen ------------- Starter Cool Down [ 1sec] [ ] Gen Cool Down [ 30sec] [ ] Leave 30s in case of manual start from panel Gen Spin Down [ 600sec] [ 540sec] Inova board does 360 sec cool down... Max Runtime [ 8hours] [ 0hours] Exercise per [ 21days] [ ] Inova options for Exercise Dur [ 30 min] [ ] warm-up / cool-down Exercise Time [ 9:00] [ ] 300s 600s Relay 3 [ NotUsed] [ ] ->300s 360s Gen Run Hold Time [ 0.0s] [ ] 60s 360s Crank Delay [ 0sec] [ ] 60s 120s Crank Time [ 0sec] [ ] Crank Retry Time [ 0sec] [ ] Preheat Time [ 0sec] [ ] Gen Start Tries [ 1] [ ] Per Schneider Type 8 is NFG, it needs AC2 soonest Exercise time interval starts from last time generator was run for any reason ================ XW SCP xx: menus XW SCP xx: Setup # xx == "up", "bsmt" ------------- Brightness [ 60%] [ 80%] Contrast [ 60%] [ 80%] *Backlight Timeout [ 2] [ 10] Light Timer [ 2mins] [ ] Button Beep [ Off] [ On] Fault Alarm [ Off] [ On] @LowBatt Alarm [ Off] [ On] Set Degrees [Fahrenheit] [ ] *Time Format [ AM/PM] [ 24-Hour] @Name [ ] [XW SCP xx] *Periodic Transmit Enable *Identify Enable ================ Combox config see Combox/README.Combox ================ Device Info XW6048 00 Model # 865-6848-01 # upgraded 2014-09-27 from 865-1000 Serial # 1626778 # upgraded 2014-09-27 from 00001473DCC7 F/W Rev. V02.00.00-0020 # upgraded 2014-09-27 from 1.07.00 BN 3 XW SCP up Model # 865-1050 Serial # 00001482AA29 F/W Rev. 1.06.00 BN 19 # upgraded 2014-08-09 from 1.05.00 BN 1 XW SCP bsmt Model # 865-1050 Serial # 000016AB6D7E F/W Rev. V02.00.00-0013 # upgraded 2014-09-24 from 1.06.00 BN 19 XW AGS 00 Model # 865-1060-01 Serial # 000016B753C2 F/W Rev. 3.00.00 BN 2 Combox Model # 865-1058 MAC 00:00:54:fe:07:bb Serial # B12884021 IP 192.168.111.116 F/W Rev. (see README.Combox) ## defective unit returned 2014-09-12 ##XW AGS 00 ##Model # 865-1060 ##Serial # 0000140919B1 ##F/W Rev. 2.07.00 BN 2 # upgraded 2014-08-11 from 2.06.00 BN 12 ================ -------- Xanbus wiring T == RS485 120ohm terminator Cat5e, minimum cable length 6.5' 2m), max total network length 131' (40m) Documentation says use T568A termination but Xantrex tech support confirmed that consistent use of T568B is fine (that is the in-house standard) [SCP bmst] [AGS ] [Combox ] [XW+ 6848] [SCP up ] T\______7'______/\______13'_____/\______7'______/\______49'_____/T -------- AUX port (see pp3-5+ of Conext-XW-Installation-Guide-NA-975-0239-01-01_Rev-H_ENG.pdf) The +12VDC AUX port output is asserted when the battery voltage drops below Trigger Level for Trigger Delay, and clears when it rises above Clear Level for Clear Delay. That output engages the time delay relay which in turn sends +12VDC to the contactor in the desirable loads panel JU is the five pin AUX port connector JU-1 AUX+12V +12VDC 250mA when AUX output triggered JU-3 AUX-COM Common ground reference TD is the time delay relay Schneider Magnacroft TDRSOXB-12V TD-A coil TD-B coil TD-1 NC TD-4 NO TD-7 common R is the contactor in the desirable loads panel (DLP) R-a coil R-b coil JU-1___________TD-A______TD-7 JU-3___________TD-B______R-a (coil) TD-1______R-b (coil) TD-4_____________R-a (coil) JU-1_________________ \ JU-3 _________TD-A TD-B_____________R-b (coil) \ \ \__TD-7 /mnt/nfs/local/docs/House/PV/Xantrex/xantrex.txt